PACTware 4.1
PACTware Consortium e.V.

Copyright (C) 1999-2011 PACTware Consortium e.V.
All rights reserved
===============================================================================
Contents
===============================================================================
 1. Overview
 2. Software requirements
 3. Hardware requirements
 4. Installation
 5. Deinstallation
 6. Start PACTware
 7. Known Problems
 8. Changes in this version
 9. Error messages
10. Download .Net Framework 2.0

===============================================================================
1. Overview
===============================================================================
 PACTware (Process Automation Configuration Tool) is a program designed to combine
 communication-capable field devices of different vendors in projects.
 PACTware is used in accordance with the FDT Specification 1.2.1 (Field Device Tool Specification) 
 as frame program for DTMs (Device Type Manager), which are provided as configuration software 
 by field device vendors. The communication with field devices using protocols like
 e.g. the HART or Profibus protocol is established via a CommDTM (Communication DTM).
  
===============================================================================
2. Software requirements
===============================================================================
 PACTware runs under the operating system Windows XP, Windows Vista and Windows 7. 
 To use the print functions and Online Help MS Internet Explorer 4.0 or higher is required.
 
 Windows 95, 98, ME, NT 4.0 and Windows 2000 are not supported by this PACTware release.

===============================================================================
3. Hardware requirements
===============================================================================
 PACTware requires 100 MByte disk space, 50 MByte main memory. 
 It is recommended to use a computer with III 400 MHz processor or higher, 
 XGA graphics and a Microsoft compatible mouse or an equivalent pointing device
 is required.
 
 Please also note the hardware requirements of device drivers.
 
===============================================================================
4. Installation
===============================================================================
 Under Windows XP/Vista/7 Administrator Rights are required.

 Before you install PACTware to the computer, close all running programs.
 In addition, the .net Runtime Environment Version 2.0 must be installed on your PC before installing PACTware.

 The Setup-File PACTware41setup.zip contains
 the Base-Setup for PACTware 4.1 with Online-Help in several languages
 the HART CommDTM for PACTware 4.1 and the Generic HART DTM
 
 After unpacking the installation into a temporary directory it is started by a 
 double-click on Setup.exe.
 
 After selecting the installation language the user is guided through the installation.

 An individual setup requesting user input starts automatically for the HART CommDTM and the 
 Generic HART DTM.
 
 If PACTware 3.0, 3.5, 3.6, or PACTware 4.0 were installed on the PC, all passwords 
 for PACTware 4.1 can be transferred at the end of the installation. 

 PACTware 2.4, 3.0 and 3.6 can be used on the same PC in parallel.

 A program group is entered to the Windows Start menu
 for the current user and a link to PACTware 4.1 is displayed on the desktop.

===============================================================================
5. Uninstall
===============================================================================
 PACTware is uninstalled via menu item "Uninstall PCATware 4.1" in the program group
 named PACTware 4.1.
 
 Exit PACTware before you start the uninstall program,
 otherwise it is impossible to uninstall all components.

===============================================================================
6. Start PACTware
===============================================================================
 PACTware is always delivered with at least one DTM. Before starting
 PACTware, the DTM and its setup program must have been installed.

 PACTware is either started by a double-click on the link on the desktop or in the Windows 
 Start menu via <Programs> in the installed program group using
 entry PACTware 4.1.

===============================================================================
7. Known Problems
===============================================================================
7.1 If only the tree view of the device catalogue is displayed under certain conditions, execution of  
PACTwareResetSettings.reg file delivered with the installation .zip file sets default width of 
the tree view sub window again.

7.2 In older Microsoft Internet Explorer versions only the left part is displayed when printing DTM parameters 
and project trees. As of Internet Explorer, Version 7 the entire print preview is displayed.

7.3 When using Softing CommDTM release 2.04 without a valid license and opening an existing project using this 
DTM, the program could crash. A valid license is required.

7.4 Due to a restriction to install PACTware 4.0 if PACTware 4.1 is already installed
PCATware 3.6 is also not installable. If you need PACTware 3.6 you have therefore
temporarily to uninstall PACTware 4.1. After finishing installation of PACTware 3.6
you can reinstall it.

===============================================================================
8. Changes in this version
===============================================================================
8.1 The new diagnostic Scan Addin collects NAMUR status information from the field devices
    if the DTMs were implemented according to the FDT 1.2.1 specification and support the
    semantic domain "PACTware".
  
    Additionally it is able to generate status information according to NE107 for
    - HART devices
    - Profibus devices implementing PA Profile 3.02 and higher  
    if the gateway/communication DTM supports multiple connections to a single device.    
    
8.2 Topology scan is provided for FDT 1.2 (HART+Profibus) and FDT 1.2.1 DTMs    

8.3 PACTware 4.1 supports the communication protocols
    - HART Release 5
    - Profibus
    - Profinet IO
    - Interbus
    - CanOpen
    - Modbus
    - Foundation Fieldbus (FF)
    - CIP
    - IO-Link

===============================================================================
9. Error messages
===============================================================================
 In case of  DTM- or PACTware-related problems, contact the hotline at
 hotline@pactware.com or call +49 (0) 7240 9430967.

 Information about the vendor of PACTware is contained in a form, which is called 
 via menu item About  in the help menu.

 Information about the DTM can be obtained either via menu item Properties
 by opening the context menu of the device in the project structure or via the Info key
 in the device catalogue of after selecting the concerned device from the catalogue. 

 Please state the operating system PACTware runs under as well as the PACTware 
 and DTM program versions. Any information about the interactions and/or the 
 implemented functions, which may have caused the problem, are appreciated 
 for trouble-shooting. In addition, screen shots are helpful in the analysis.

===============================================================================
10. Download .Net Framework 2.0
===============================================================================
 Link to Download .NET Framework 2.0:
http://www.microsoft.com/downloads/details.aspx?familyid=0856EACB-4362-4B0D-8EDD-AAB15C5E04F5&displaylang=en